The Focusun brine block ice machine is a traditional and reliable ice production system that uses salt water (brine) as a heat exchange medium. It is an ideal solution for large-scale industrial ice production, particularly in ports, fisheries, and tropical environments.
If you require a brine-type block ice machine with a daily output of more than 15 tons, you will need to build a brine tank and install an overhead crane in your factory. Don’t worry—Focusun engineers will provide you with a free design solution tailored to your actual site conditions.
In addition, the ice molds used in brine-type block ice machines are quite unique. To facilitate the quick release of ice blocks after the freezing process, the molds are typically designed in a tapered shape—wider at the top and narrower at the bottom.
There are two main materials available for the ice molds:
Equipping your ice factory with a cold storage room is essential. Once the ice blocks are produced, they are typically transported to the cold room for proper storage.
| Subject | Unit | Technical parameter | |
| Power supply | Voltage/Phase/Frequency | 220V~480V/3P/50~60Hz | |
| Refrigerant | / | R22/R404A/R507A/R448A/R449A/R717 | |
| Capacity | Kg/day | 30000 | |
| Temperature | Ambient temperature | ℃ | 35 |
| Water inlet temperature | ℃ | 20 | |
| Operating power | Total running power | Kw | 120.3 |
| Installment power | Kw | 150 | |
| Operating power of cold water pump | Kw | 7.5 | |
| Compressor | Manufacturer | Bitzer | |
| Refrigeration capacity | Kw | 236.4 | |
| Operating power | Kw | 101.6 | |
| Compressor COP/EER | Kw/kw | 2.3 | |
| Horse power | Hp | 40×4 | |
| Condenser | Power | Kw | 11.2 |
| Cooling way | Water cooling | ||
| Working time | Ice making time | h | 7.5 |
| Ice doffing time | h | 0.5 | |
| Dimension | Weight of each block | Kg/block | 50 |
| Size of block ice | (L×W×H)(mm) | 480×160×700 | |
| Size of cooling tower | (L×W×H)(mm) | φ3300×2785mm | |
| Size of water feeding pipe | 1-1/4" | ||
| Operating weight of cooling tower | Kg | 2730 | |
| Water supply pressure requirement | Bar | 1 | |